Products
Profiler
T4
T6V4
RTD6
GP4
GP8
VB1
VB1000T
VB2000T






Click Here

MMS3000 SERIES
Measures and records 4 channels of temperature EASILY!
At a Glance...
T4


24 bit A/D converter.

ProFlash upgradeable firmware.

MAS™ Windows based software.

512 Kilobyte non volatile memory. (Approx 400,000 samples)

4.3"x2.3" (100mmx60mm) LCD screen.

Long-life Nicad battery pack.

RS232 Interface with cable.

3 Year Warranty (on instrument only).
MMS3000 T4

Temperature monitoring has been a task relegated to simple and unexciting chart recorders. Think temperature recording and you think clumsy boxes that require constant attention with paper and pen refills. This is no longer true with the MMS3000-T4.

The MMS3000-T4 is the low-cost temperature-dedicated product in the revolutionary MMS3000 series. With the MMS3000-T4 you can take extended recordings of up to 9,999 readings, and up to 60 hours between samples. The result is a test that can last weeks without the need to touch anything. Once finished, simply connect the unit to a standard PC and within minutes your data is easily downloaded for further analysis using MAS™, our Windows based data manipulation software.

Do you need to review temperature data in the field or on the plant floor away from a PC? Then the MMS3000-T4 is the instrument of choice. The large LCD enables you to graphically review recorded data simply by pressing a few keys.


MAS screen shots
Windows based software for flexible data manipulation.
Producing a variety of graphs and printout options.

Available for Download

User Manual

Product Specification PDF Document

Software/Firmware

Specifications
ITEM
SPEC
REMARKS

Model: MMS3000-T4
Incorporating 4 Temperature Channels


  TEMPERATURE RANGE
T Type Thermocouple
-418 to +743°F (-250 to +395°C)
Operating temperature range
E Type Thermocouple
-418 to +1823°F (-250 to +995°C)
is determined by operating
J Type Thermocouple
-346 to +2183°F (-210 to +1195°C)
range of thermocouple
K Type Thermocouple
-418 to +2498°F (-250 to +1370°C)

  TEMPERATURE RESOLUTION

Above -148°F (-100°C): 0.1°F or °C


At or below -148°F (-100°C): 1°F or °C
Effective resolution decreases at or below -148°F (-100°C)
  TEMPERATURE ACCURACY

Above -148°F (-100°C): ?.1% of reading ?.9°F (0.5°C)
At or below -148
°F (-100°C): ?% of reading ?.9°F (0.5°C)
Total measurement accuracy depends on MMS3000-T4 and thermocouple accuracy. Only MMS3000-T4 accuracy is given here. MMS3000-T4 temperature 73 ?9°F (23 ?5°C), charger off. See Appendix 3 of Owners Manual
  MINIMUM SAMPLING INTERVAL

# of channels selected
(User-selectable)

Minimum sampling interval
(seconds)

1
0.2
2
0.3
3
0.5
4
0.6
Sampling interval is programmable from 0.2 seconds to 60 hours

Note: Minimum time to scan all selected channels - not each channel

  DATA LOGGING
Data Storage
512 kilobytes ?approx. 400,000 individual samples
Non-volatile memory (with battery back-up). # of Samples depends on # of Data Sets and Recordings.
Data Storage Format
Up to 50 named DATA SETS
User-specified name entered from keypad

Up to 50 RECORDINGS per data set
Each recording has unique time/date stamp

Up to 9,999 SAMPLES per recording
Each sample contains data for all selected channels
Data Set Name
Up to 16 alpha-numeric characters

  DISPLAY

LCD with graphic capabilities

Resolution
240 x 128 pixels

Viewing Area
4.3" x 2.3" (110mm x 60mm)

Backlight
Electro-luminescent

 PROFLASH

Allows internal firmware to be upgraded via built-in RS232 port
Download firmware upgrades via the Internet
 COMMUNICATIONS

RS232
15kV ESD Protected. Cable with DB9 connector included
Baud Rate
9600, 19200, 57600 bits per second
Automatic Baud Rate Selection
  INPUT TERMINATION

Sockets accept miniature thermocouple twin blade plug
Blades spaced 5/16" (7.9mm) center-to-center
  INPUT IMPEDANCE

Greater than 100k Ohms
Terminal-to-terminal
  ISOLATION

50VDC minimum
Between temperature inputs and MMS3000-T4 outputs e.g. RS232 port. No isolation between input channels.
  BATTERY
Type
Custom Nickel-Cadmium pack

Voltage
7.2 Volts nominal

Capacity
1500 mAh nominal

Operating Time
13 hrs with backlight off, 7 hrs backlight on - nominal

  CHARGER AND CONDITIONER

Built-in dual rate charger ?Automatic and Manual control
AC Adapter included (13.5 ?1.5 VDC, 1A output)
Fast Charge Rate
0.7A nominal
2.5 hours for complete charge nominal
Discharge Rate
0.5A nominal
Combats NiCad battery memory effect
  MECHANICAL
Size
9.7"W x 6.1"L x 3.0"H (247mm x 154mm x 75mm)
Including protective boot
Weight
4.4lb (2kg)
Including protective boot and strap
  ENVIRONMENTAL
Temperature/Humidity


Operating
32°F to 122°F (0°C to 50°C) / 70% RH
Non-condensing

32°F to 86°F (0°C to 30°C) / 80% RH
Non-condensing
Storage
14°F to 140°F (-10°C to 60°C ) / 95% RH

EMC
EN50081-1
Radiated and conducted emissions

EN50082-1
ESD Immunity and RF field immunity (EMI).
The manufacturer reserves the right to modify specifications without prior notice.