| Performance |
| |
Display wave patterns on time
scale |
| |
Transient recording (memory capacity
max.32k words) |
| |
Linear spectrum |
| |
Three-dimensional display of spectrum |
| |
10 largest spectra chosen and
displayed |
| |
Automatic diagnosis: imbalance,
misalignment, abnormal bearing, damaged gear, play, loosening,
trouble of Pump₯Motor |
| |
Field balance |
| |
1/3 Octave analysis(MK-500D only) |
| |
Probability density function(MK-500D
only) |
| |
Probability distribution function(MK-500D
only) |
| |
Differential and integral of spectrum(MK-500D
only) |
Input unit
| Input channel
|
One channel |
| Input impedance |
1MΆ(voltage input) |
| Input coupling |
Vibration/AC(3Hz,-3dB)
Voltage/AC(2Hz,-3dB),DC |
| Attenuator
range |
Vibration/displacement
50,150,500,1500,
5000ΚmP-P
Velocity 0.5,1.5,5,15,50cm/s O-P
Acceleration 0.5,1.5,5,15,50G O-P
ENV 0.5,1.5,5,15,50G O-P
Voltage/AC/DC }0.1,0.5,1.5,10,50V
Audio sound 80,100,120dB Flat |
Low pass filter
(Vibration input only) |
Cut-off
frequency 1kHz,40kHz,None |
High pass filter
(Vibration input only) |
Cut-off frequency
2Hz,5Hz,10Hz,1kHz,5kHz |
| Input terminal |
@Vibration input(metal
receptacle)/vibration pickup PU-616B handheld(standard)
AVoltage input (BNC)/for sound analysis Micro-phone (option) |
| Trigger mode |
Free-run mode,
repeat mode, single mode |
| Trigger level |
Continuously
variable within the range of vibration and voltage |
| Trigger polarity |
Positive or negative |
| Trigger
point |
Setting
available between
-1,024+1,024 points |
Analysis unit
| Frequency
range |
10,20,50,100,200,500,1k,2k,5k,10k,
20k,50kHz...12ranges |
| Number
of sampling points |
1,024points |
| Frequency
resolution |
1/400 of analysis
range |
| Spectral
lines |
400(LCD display) |
| Dynamic
range |
60dB and larger |
| A/D
resolution |
12bit/word |
| Sampling
frequency |
2.56 timcs the
analysis frequency range |
| Window
function |
Hanning, Hamming,
Rectangular |
| Average
mode |
Linear average
on frequency axis |
| Number
of averaging |
2,4,8,16 and
32 times |
| Anti-aliasing
filter |
Butterworth-48dB/oct
or larger |
|
Display
unit
| Display method
|
LCD graphic (with
back light) |
| Display dimension |
62~230mm(2.44~9.06ins)
(128~480dots) |
| Field of vision |
Angle can be
changed by control volume |
| X-axis scale |
Frequency or
time(linear) |
| Y-axis scale |
Level(linear
and logarithm) |
| Display by letters |
Input, analysis,
diagnosis, condition |
Output unit
| Output |
Analog output(wave
pattern)
Digital output(RS-232C) |
Memory unit
| |
Transient memory(capacity
32K words) |
| |
240 display pictures
of analysis data can be stored (which may be brought back to
the office for data processing being backed up by batteries) |
| |
Panel condition memory
(when the power source is made OFF and then ON, the setting
conditions at the time of power OFF is automatically reestablished) |
| |
240 display pictures
per memory card can be stored.(option) |
Warning and protection unit
| |
When an abnormal condition is
found as a result of automatic diagnosis, warning sound is issued.
|
| |
Low battery warning sound is reduced
to 11.0V and lower,a mark on LCD flickers. |
| |
Battery level display |
General specification
| Internal
power |
Seal
type lead battery 12V/2.2Ah |
| External
power |
Commercial
AC source (any voltage upon request)
DC11.5`30V,0.8A |
| Power
consumption |
Approx,
4W |
| Continuous
operation |
5.5h
or more (for nomal usage) |
| Operating
temperature |
0`40(32`104F) |
| Storing
temperature |
-10`60(14`140F) |
| External
dimensions |
295(W)~236(D)~135(H)mm
(11.61~9.29~5.31ins) |
| Weight |
Approx
5.0kg(11.02lbs)
(including battery) |
Standard setup
| |
One MK-500 with carrying
case |
 |
| |
One vibration pickup
: selected from the three choices |
|
| -1 |
Magnet type PU-616B with 5m cable |
|
|
| -2 |
: Magnet type PU-626B with 5m cable |
|
|
| -3 |
: Handy type PU-601R with 1m cable |
|
| |
One AC adaptor, also
applicable to battery charger |
| |
Operation
manual |
Option
| |
Printer : DPU-201GS |
| |
Memory card : MK-8210 |
| |
Microphone for audio sound : EMU-4535
U |
| |
LED Detector for Field Balancing
with fixing magnetic stand: CRD-300CN |
| |
Magnet for pickup |
|